Two-way control valves RV 102 and three-way RV 103

Two-way control valves RV 102 and three-way RV 103

Nominal size: DN 15, DN 50
Working pressure: PN 16
Working temperature: 0 to 150 °C
Connection parameters: ČSN-EN ISO 228-1 resp. ČSN-EN 1092-1
Face-to-face length: series M4 according to DIN 3202, series 1 according to ČSN-EN 558-1
Materials: Body - bronze
Leak test: class III according to ČSN-EN 1349 in branches A-AB

Hi, my name is Marko. I am ready to assist you.

Ing. Marko Štofan

Valve series RV 102 and RV 103 are designed to regulate the flow and pressure of liquids, gases and vapours without abrasive particles e.g. water, low-pressure steam, (it applies to RV 102 only, RV 103 valves are not suitable for steam or steam condensate), air and other media compatible with material of the valve inner parts. 

More information from manufacturer - RV 102
More information from manufacturer - RV 103

 

Similar products

Explosion-proof electric linear actuator ST 1-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min Operating stroke: 8 to 80 mm
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off thrust: 2300 to 10000 N

Explosion-proof electric linear actuator UL 0-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 6900 N Operating speed: 10 to 80 mm/min Operating stroke: 4 to 40 mm
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 6900 N

Explosion-proof electric linear actuator UL 1-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 12500 N Operating speed: 10 to 80 mm/min Operating stroke: 10 to 80 mm
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 12500 N

Explosion-proof electric linear actuator UL 2-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off thrust: 7000 to 25000 N Operating speed: 14 to 120 mm/min Operating stroke: 10 to 120 mm
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off thrust: 7000 to 25000 N

Electric linear actuator ST MINI

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off thrust: 250 to 1100 N Operating speed: 5 to 40 mm/min Operating stroke: 6 to 25 mm
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off thrust: 250 to 1100 N

Explosion-proof electric linear actuator MT 3-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off thrust: 4800 to 36000 N Operating speed: 32 to 180 mm/min Operating stroke: 10 to 100 mm
Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off thrust: 4800 to 36000 N

Electric linear actuator ST 0

Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off thrust: 360 to 4500 N Operating speed: 5 to 40 mm/min Operating stroke: 8 to 40 mm
Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off thrust: 360 to 4500 N

Electric linear actuator ST 0.1

Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 1900 to 7200 N Operating speed: 10 to 63 mm/min Operating stroke: 50 mm
Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 1900 to 7200 N

Electric linear actuator ST 1

Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min Operating stroke: 8 to 80 mm
Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N

Electric linear actuator UL 0

Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 6900 N Operating speed: 10 to 80 mm/min Operating stroke: 4 to 40 mm
Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 6900 N

Category products

Two-way control valves RV 102 and three-way RV 103

Nominal size: DN 15, DN 50 Working pressure: PN 16 Working temperature: 150 °C Connection parameters: ČSN-EN ISO 228-1 resp. ČSN-EN 1092-1 Face-to-face length: series M4 according to DIN 3202, series 1 according to ČSN-EN 558-1
Nominal size: DN 15, DN 50 Working pressure: PN 16 Working temperature: 150 °C

Two-way control valves RV 113 R and three-way RV 113 M

Nominal size: DN 15, DN 150 Working pressure: PN 6, PN 16, PN 25 Working temperature: 150 °C Connection parameters: ČSN-EN 1092-1 (flange type B1) Face-to-face length: row 1 according to ČSN-EN 558-1 + A1
Nominal size: DN 15, DN 150 Working pressure: PN 6, PN 16, PN 25 Working temperature: 150 °C

Two-way shut-off and control valves Series RV 2x0 (Ex)

Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 150 °C Connection parameters: ČSN-EN 1092-1 (flange type B1) Face-to-face length: row 1 according to ČSN-EN 558-1
Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 150 °C

Three-way shut-off and control valves Series RV 2x4 (Ex)

Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 300 °C Connection parameters: ČSN-EN 1092-1/2 (flange type B1) Face-to-face length: row 1 according to ČSN-EN 558
Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 300 °C

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts