Shut-off valves V30 115 616

Shut-off valves V30 115 616

Nominal size: DN 15, DN 150
Working pressure: PN 16
Working temperature: 0 to 300 °C
Face-to-face length: EN 558-1
Materials: Body - Gray cast iron GG25, Cone - Stainless steel, Saddle - Stainless steel

Hi, my name is Marko. I am ready to assist you.

Ing. Marko Štofan

Application: Shut-off or discharge fitting for liquid and gaseous media. Valves are not suitable as a regulatory body.

Fields of application: industrial processes, heating, refrigeration, air conditioning, water management.

Medium: water, steam, air and non-aggressive liquids and gases.

Permissible pressures and temperatures: see detailed catalog sheet

For further information, see detailed catalog sheet or on request.

Similar products

Explosion-proof electric part-turn actuator UP 0-Ex

Type number: 335 Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off torque: 7.5 to 63 Nm Operating time: 5 to 80 s/90°
Type number: 335 Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68

Electric part-turn actuator UP 1-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 22 to 170 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 ° Weight: 14 to 15 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 22 to 170 Nm Operating time: 5 to 80 s/90°

Electric part-turn actuator UP 2-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 75 to 300 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 ° Weight: 26 to 34.2 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 75 to 300 Nm Operating time: 5 to 80 s/90°

Explosion-proof electric linear actuator ST 1-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min Operating stroke: 8 to 80 mm
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off thrust: 2300 to 10000 N

Electric part-turn actuator UP 2.4-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 110 to 800 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 ° Weight: 29 to 33 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 110 to 800 Nm Operating time: 20 to 160 s/90°

Electric part-turn actuator UP 2.5-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 300 to 1800 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 ° Weight: 48 to 52 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 300 to 1800 Nm Operating time: 20 to 160 s/90°

Electric linear actuator ST 0

Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off thrust: 360 to 4500 N Operating speed: 5 to 40 mm/min Operating stroke: 8 to 40 mm
Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off thrust: 360 to 4500 N

Electric linear actuator ST 1

Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min Operating stroke: 8 to 80 mm
Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N

Electric linear actuator ST 1-M

Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min Operating stroke: 8 to 80 mm Weight: 8.5 to 13 kg
Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min

Explosion-proof electric part-turn actuator UP 0-Ex-M

Type number: 335 Enclosure protection: IP 66, IP 68 Switching-off torque: 7.5 to 63 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Type number: 335 Enclosure protection: IP 66, IP 68 Switching-off torque: 7.5 to 63 Nm

Category products

Shut-off valves V30 115 616

Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C Face-to-face length: EN 558-1 Materials: Body - Gray cast iron GG25, Cone - Stainless steel, Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C

Shut-off valves V30 115 540

Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C Face-to-face length: EN 558-1 Materials: Body - Steel 42 2643, Cone - DN 15 – 100 (Stainless steel), DN 125 – 150 (Carbon steel), Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C

Bellows shut-off valves V25 115 540

Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -20 to 400 °C Face-to-face length: EN 558-1 Materials: Body - Steel 42 2643, Cone - DN 15 – 50 (Stainless steel), DN 65 – 150 (Carbon steel), Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -20 to 400 °C

Control valves V41 115 616

Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C Face-to-face length: EN 558-1 Materials: Body - Gray cast iron GG25, Cone - Stainless steel, Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C

Control valves V41 115 540

Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C Face-to-face length: EN 558-1 Materials: Body - Steel 42 2643, Cone - Stainless steel, Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts