Electric linear actuator ST 1-M

Electric linear actuator ST 1-M

Enclosure protection: IP 65, IP 67, IP 68
Switching-off thrust: 2300 to 10000 N
Operating speed: 8 to 80 mm/min
Operating stroke: 8 to 80 mm
Weight: 8.5 to 13 kg
Ambient temperature: -25 to 55 °C

Hi, my name is Marko. I will be glad to help you.

Ing. Marko Štofan

Standard equipment

  • Supply voltage:
    • 230 V / 50 Hz
  • Terminal board connection
  • Thermal protection of electromotor
  • 2 thrust switches
  • 2 position switches
  • Mechanical connection according to ISO 5210 - flange size F05
  • Manual control
  • Mechanical position indicator
  • Enclosure protection IP 65

Additional equipment 

  • Supply voltage:
    • 3x400 V, 3x380 V, 220 V, 24 V / 50 Hz
    • 24 V DC
  • Connector connection
  • Position transmitterl:
    • potentiometer single/double, 1x100 Ω, 1x2000 Ω, 2x100 Ω, 2x2000 Ω
    • electronic position transmitter, active/passive, 2-wire/3-wire, 0/4 to 20 mA
    • current CPT, active/passive, 2-wire/3-wire, 0/4 to 20 mA
  • 2 additional position switches
  • Space heater with/without thermal switch
  • Gold coated contacts of microswitches
  • Electric local control unit
  • Enclosure protection IP 67 / IP 68

Similar products

Control valves V41 115 540

Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C Face-to-face length: EN 558-1 Materials: Body - Steel 42 2643, Cone - Stainless steel, Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C

Control valves V41 115 616

Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C Face-to-face length: EN 558-1 Materials: Body - Gray cast iron GG25, Cone - Stainless steel, Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C

Bellows shut-off valves V25 115 540

Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -20 to 400 °C Face-to-face length: EN 558-1 Materials: Body - Steel 42 2643, Cone - DN 15 – 50 (Stainless steel), DN 65 – 150 (Carbon steel), Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -20 to 400 °C

Shut-off valves V30 115 540

Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C Face-to-face length: EN 558-1 Materials: Body - Steel 42 2643, Cone - DN 15 – 100 (Stainless steel), DN 125 – 150 (Carbon steel), Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 40 Working temperature: -50 to 400 °C

Shut-off valves V30 115 616

Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C Face-to-face length: EN 558-1 Materials: Body - Gray cast iron GG25, Cone - Stainless steel, Saddle - Stainless steel
Nominal size: DN 15, DN 150 Working pressure: PN 16 Working temperature: 300 °C

Three-way shut-off and control valves Series RV 2x4 (Ex)

Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 300 °C Connection parameters: ČSN-EN 1092-1/2 (flange type B1) Face-to-face length: row 1 according to ČSN-EN 558
Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 300 °C

Two-way shut-off and control valves Series RV 2x0 (Ex)

Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 150 °C Connection parameters: ČSN-EN 1092-1 (flange type B1) Face-to-face length: row 1 according to ČSN-EN 558-1
Nominal size: DN 15, DN 400 Working pressure: PN 6, PN 16, PN 25, PN 40 Working temperature: -10 to 150 °C

Two-way control valves RV 113 R and three-way RV 113 M

Nominal size: DN 15, DN 150 Working pressure: PN 6, PN 16, PN 25 Working temperature: 150 °C Connection parameters: ČSN-EN 1092-1 (flange type B1) Face-to-face length: row 1 according to ČSN-EN 558-1 + A1
Nominal size: DN 15, DN 150 Working pressure: PN 6, PN 16, PN 25 Working temperature: 150 °C

Two-way control valves RV 102 and three-way RV 103

Nominal size: DN 15, DN 50 Working pressure: PN 16 Working temperature: 150 °C Connection parameters: ČSN-EN ISO 228-1 resp. ČSN-EN 1092-1 Face-to-face length: series M4 according to DIN 3202, series 1 according to ČSN-EN 558-1
Nominal size: DN 15, DN 50 Working pressure: PN 16 Working temperature: 150 °C

Category products

Electric linear actuator ST 0-M

Enclosure protection: IP 54, IP 67, IP 68 Switching-off thrust: 360 to 4500 N Operating speed: 5 to 40 mm/min Operating stroke: 8 to 40 mm Weight: 2.5 to 4.5 kg
Enclosure protection: IP 54, IP 67, IP 68 Switching-off thrust: 360 to 4500 N Operating speed: 5 to 40 mm/min

Electric linear actuator ST 1-M

Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min Operating stroke: 8 to 80 mm Weight: 8.5 to 13 kg
Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min

Electric linear actuator ST 2-M

Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 9000 to 25000 N Operating speed: 10 to 120 mm/min Operating stroke: 8 to 100 mm Weight: 17 to 23 kg
Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 9000 to 25000 N Operating speed: 10 to 120 mm/min

Electric linear actuator UL 0-M

Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 1400 to 6900 N Operating speed: 10 to 80 mm/min Operating stroke: 25 to 40 mm Weight: 6.5 to 8.5 kg
Enclosure protection: IP 65, IP 67, IP 68 Switching-off thrust: 1400 to 6900 N Operating speed: 10 to 80 mm/min

Electric linear actuator UL 1-M

Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 12500 N Operating speed: 10 to 80 mm/min Operating stroke: 10 to 80 mm Weight: 16 to 19.5 kg
Enclosure protection: IP 66, IP 68 Switching-off thrust: 1400 to 12500 N Operating speed: 10 to 80 mm/min

Electric linear actuator UL 2-M

Enclosure protection: IP 66, IP 68 Switching-off thrust: 7000 to 25000 N Operating speed: 14 to 120 mm/min Operating stroke: 10 to 100 mm Weight: 26 to 34.2 kg
Enclosure protection: IP 66, IP 68 Switching-off thrust: 7000 to 25000 N Operating speed: 14 to 120 mm/min

Electric linear actuator MT 3-M

Enclosure protection: IP 67, IP 55 Switching-off thrust: 4800 to 36000 N Operating speed: 32 to 250 mm/min Operating stroke: 10 to 100 mm Weight: 30 to 35 kg
Enclosure protection: IP 67, IP 55 Switching-off thrust: 4800 to 36000 N Operating speed: 32 to 250 mm/min

Electric linear actuator MTR-M

Enclosure protection: IP 67, IP 55 Switching-off thrust: 2500 to 25000 N Operating speed: 38 to 120 mm/min Operating stroke: 12.5 to 100 mm Weight: 27 to 46 kg
Enclosure protection: IP 67, IP 55 Switching-off thrust: 2500 to 25000 N Operating speed: 38 to 120 mm/min

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts