Explosion-proof electric multi-turn actuator MO 3-Ex

Explosion-proof electric multi-turn actuator MO 3-Ex

Type number: 100
Industry use: Oil and gas, Dust
Enclosure protection: IP 66
Switching-off torque: 26 to 150 Nm
Operating time: 16 to 95 min−1
Revolutions: 1 to 685
Weight: 45 to 55 kg
Ambient temperature: -50 to 60 °C
Flange size: F10, F14
Mouting position: with the motor axis in a horizontal position (deviation +/-15°)
Type of protection: II 2G Ex db eb IIC T5/T4 Gb, II 2D Ex tb IIIC T135°C Db
contact Configurator

Hi, my name is Marko. I will be glad to help you.

Ing. Marko Štofan

Standard equipment

  • Supply voltage:
    • 3x400 V / 50 Hz
  • Terminal board connection
  • Thermal protection of electromotor PTO (shut-off temperature 150°C)
  • 2 torque switches
  • 2 position switches
  • 2 additional position switches
  • Space heater with thermal switch
  • Mechanical connection ISO 5210, flange size F10, shape B3, D and non-standard shape C
  • Local position indicator
  • Torque switches blocking in limit positions
  • Manual control
  • Enclosure protection IP 66

Additional equipment

  • Supply voltage:
    • 3x380 V, 230 V, 220 V / 50 Hz
  • Thermal protection of electromotor 3PTC (shut-off temperature 150°C)
  • Tandem switches
  • Position transmitter:
    • potentiometer single/double, 1x100 Ω, 1x2000 Ω, 2x100 Ω, 2x2000 Ω
    • electronic position transmitter, active/passive, 2-wire/3-wire, 0/4 to 20 mA
    • electronic position transmitter, active/passive, 3-wire, 0 to 10 V
    • current CPT, active/passive, 2-wire/3-wire, 0/4 to 20 mA
    • current DCPT 3M, active/passive, 2-wire, 4 to 20 mA
  • Electrical local control unit
  • Gold coated contacts of microswitches
  • Mechanical connection:
    • ISO 5210, flange size F10, shape A, B1
    • ISO 5210, flange size F14, shape C
    • ГOCT P 55510, shape AK, AČ
    • other non-standard
  • Enclosure protection IP 67

Similar products

Wedge, lid or yoke sliders

Nominal size: DN 50, DN 600 Working pressure: PN 16 Working temperature: 70 °C Connection parameters: PN EN 1092-2, ISO 7005-2 Face-to-face length: ANSI B16.1, flange design EN 558, series 15, DIN 3202-1/F5, welding version EN 12 982, series 15, (DIN 3202-1/S8)
Nominal size: DN 50, DN 600 Working pressure: PN 16 Working temperature: 70 °C

Knife gate valves

Nominal size: DN 50, DN 1000 Working pressure: PN 10/16 Working temperature: 70 °C Connection parameters: PN EN 0192-2, DIN 2501 Materials: Monolith body - ductile iron EN-GJS-400-15 (GGG-40), Wedge – fully rubberized with antibacterial EPDM, NBR, Spindle - corrosion-resistant steel 1.4021 (13% Cr), O - rings - NBR, Spindle nut – forged brass
Nominal size: DN 50, DN 1000 Working pressure: PN 10/16 Working temperature: 70 °C

Soft-sealing wedge sliders

Nominal size: DN 40, DN 1200 Working pressure: PN 10/16 Working temperature: 70 °C Connection parameters: EN 0192-2 with flanges type 21, shape B Face-to-face length: 15 – according to PN-EN 558+A1, F5 (DIN 3202), 14 – according to PN-EN 558+A1, F4 (DIN 3202)
Nominal size: DN 40, DN 1200 Working pressure: PN 10/16 Working temperature: 70 °C

Category products

Explosion-proof electric multi-turn actuator SO 2-Ex

Type number: 042 Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 7.5 to 50 Nm Operating time: 10 to 40 min−1
Type number: 042 Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67

Explosion-proof electric multi-turn actuator MO 3-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 26 to 150 Nm Operating time: 16 to 95 min−1 Revolutions: 1 to 685
Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 26 to 150 Nm

Explosion-proof electric multi-turn actuator MO 3.4-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 90 to 300 Nm Operating time: 10 to 80 min−1 Revolutions: 1.3 to 285
Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 90 to 300 Nm

Explosion-proof electric multi-turn actuator MO 3.5-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 80 to 550 Nm Operating time: 25 to 45 min−1 Revolutions: 1.5 to 185
Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 80 to 550 Nm

Explosion-proof electric multi-turn actuator MO 4-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 55 Switching-off torque: 95 to 500 Nm Operating time: 16 to 180 min−1 Revolutions: 1 to 685
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 55 Switching-off torque: 95 to 500 Nm

Explosion-proof electric multi-turn actuator MO 5-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 300 to 1000 Nm Operating time: 15 to 100 min−1 Revolutions: 1.25 to 500
Industry use: Oil and gas, Dust Enclosure protection: IP 66 Switching-off torque: 300 to 1000 Nm

Explosion-proof electric multi-turn actuator UM 1-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off torque: 4 to 64 Nm Operating time: 10 to 80 min−1 Revolutions: 3.125 to 160
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off torque: 4 to 64 Nm

Explosion-proof electric mutli-turn actuator UM 2-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off torque: 18 to 100 Nm Operating time: 10 to 40 min−1 Revolutions: 3.125 to 160
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off torque: 18 to 100 Nm

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts