Electric part-turn actuator SP 2.3

Electric part-turn actuator SP 2.3

Type number: 283
Industry use: Energy, Water, Industry
Enclosure protection: IP 67, IP 68
Switching-off torque: 290 to 350 Nm
Operating time: 20 to 160 s/90°
Operating angle: 60 to 360 °
Weight: 15 to 20 kg
Ambient temperature: -60 to 55 °C
Flange size: F07, F10
Mouting position: any
contact Configurator

Hi, my name is Marko. I will be glad to help you.

Ing. Marko Štofan

Standard equipment

  • Supply voltage:
    • 230 V / 50 Hz
  • Terminal board connection
  • Thermal protection of electromotor
  • 2 torque switches
  • 2 position switches
  • Mechanical connection according to ISO 5211, flange size F07/F10
  • Mechanical position indicator
  • Mechanical stop ends
  • Manual control
  • Enclosure protection IP 67

Additional equipment

  • Supply voltage:
    • 3x400 V, 3x380 V, 220 V, 24 V / 50 Hz
    • 24 V DC
  • Connector connection
  • Reversing unit for 3-phase supply voltage
  • 2 additional position switches
  • Position transmitter:
    • potentiometer single/double 1x100 Ω, 1x2000 Ω, 2x100 Ω, 2x2000 Ω
    • electronic position transmitter, passive/active, 2-wire/3-wire, 0/4 to 20 mA
    • CPT, passive/active, 2-wire/3-wire, 4 to 20 mA
  • Space heater with/without thermal switch
  • Electric local control unit (only to -40°C)
  • Gold coated contacts of microswitches
  • Without end stops
  • Mechanical connection according to ISO 5211, flange size F10
  • Mechanical connection with stand, lever and pulls
  • Enclosure rating IP 68

Similar products

Electric part-turn actuator SP 0-M

Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm Operating time: 15 to 160 s/90° Operating angle: 90 to 270 ° Weight: 1.4 to 2.4 kg
Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm Operating time: 15 to 160 s/90°

Electric part-turn actuator SP 0.1-M

Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm Operating time: 10 to 160 s/90° Operating angle: 60 to 360 ° Weight: 3.2 to 5.2 kg
Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm Operating time: 10 to 160 s/90°

Explosion-proof electric part-turn actuator SP 2.3-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 290 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 290 Nm

Electric part-turn actuator SP 0.1

Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm Operating time: 10 to 120 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm

Explosion-proof electric part-turn actuator SP 2.4-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 575 Nm Operating time: 40 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 575 Nm

Electric part-turn actuator SP 1

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 90 Nm Operating time: 10 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 90 Nm

Electric part-turn actuator SP 1-M

Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 100 Nm Operating time: 10 to 80 s/90° Operating angle: 60 to 360 ° Weight: 6.5 to 8.3 kg
Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 100 Nm Operating time: 10 to 80 s/90°

Explosion-proof electric part-turn actuator UP 0-Ex

Type number: 335 Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68 Switching-off torque: 7.5 to 63 Nm Operating time: 5 to 80 s/90°
Type number: 335 Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 68

Electric part-turn actuator SP 2

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 145 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 145 Nm

Electric part-turn actuator SP 2-M

Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 175 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 ° Weight: 12 to 14.5 kg
Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 175 Nm Operating time: 5 to 80 s/90°

Category products

Electric part-turn actuator SP MIKRO

Industry use: Energy, Water, Industry Enclosure protection: IP 65 Switching-off torque: 8 Nm Operating time: 120 s/90° Operating angle: 60 to 120 °
Industry use: Energy, Water, Industry Enclosure protection: IP 65 Switching-off torque: 8 Nm

Electric part-turn actuator SP 0

Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm Operating time: 15 to 160 s/90° Operating angle: 90 to 270 °
Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm

Electric part-turn actuator SP 0.1

Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm Operating time: 10 to 120 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm

Electric part-turn actuator SP 1

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 90 Nm Operating time: 10 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 90 Nm

Electric part-turn actuator SP 2

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 145 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 145 Nm

Electric part-turn actuator SP 2.3

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 290 to 350 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 290 to 350 Nm

Electric part-turn actuator SP 2.4

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 575 to 650 Nm Operating time: 40 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 575 to 650 Nm

Electric part-turn actuator UP 1

Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 22 to 170 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 22 to 170 Nm

Electric part-turn actuator UP 2

Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 75 to 300 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 75 to 300 Nm

Electric part-turn actuator UP 2.4

Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 110 to 800 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 110 to 800 Nm

Electric part-turn actuator UP 2.5

Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 300 to 1800 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 300 to 1800 Nm

Electric part-turn actuator MPR

Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 25 to 125 Nm Operating time: 8 to 34 s/90° Operating angle: 60 to 160 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 25 to 125 Nm

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts