Electric multi-turn actuator MOR 3.5PA

Electric multi-turn actuator MOR 3.5PA

Type number: 096
Enclosure protection: IP 67
Switching-off torque: 140 to 550 Nm
Operating time: 25 to 40 min−1
Revolutions: 1 to 400
Weight: 65 to 90 kg
Ambient temperature: -60 to 60 °C
Flange size: F14, F16
Mouting position: with the motor axis in a horizontal position (deviation +/-15°)
contact Configurator

Hi, my name is Marko. I will be glad to help you.

Ing. Marko Štofan

Standard equipment and functions with DMS3 control unit

  • Supply voltage:
    • 3x400 V / 50 Hz
  • Terminal board connection
  • Thermal protection of the electromotor PTO (shut-off temperature 150°C)
  • Switching off in limit positions from position and from torque
  • Adjustable switching off from 50% to 100%
  • Torque blocking in limit positions
  • Torque blocking during the start
  • 7 freely programmable relays R1, R2, RE1 ... RE5 (18 functions) (Not valid for Profibus and Modbus)
  • 2 relays READY (Not valid for Profibus and Modbus)
  • Control by unified signal 0/4 - 20 mA, 4 - 12 mA, 12 - 20 mA, or 0/2 - 10 V (Not valid for Profibus and Modbus)
  • Control by permanent voltage (+24 V DC) - OPEN, CLOSE
  • Impulse control (inching duty) (+24 V DC) - OPEN, STOP, CLOSE
  • Timing mode / regime of operation
  • Safety function ESD (failure reaction)
  • Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)
  • Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs and transmitter
  • Output of failure messages
  • Space heater operated by control unit
  • LED position indicator
  • Communication interface RS 232
  • Programme for parameterization setting a PC
  • Mechanical connection:
    • ISO 5210, flange size F14, shape B1, B2, B3, C, D
    • ISO 5210, flange size F16, shape B2, B3, C, D
  • Manual control
  • Enclosure protection IP 67

Additional equipment

  • Supply voltage:
    • 3x380 V, 230 V, 220 V / 50 Hz
  • Reversing unit for 3-phase supply voltage
  • Communication cable DB-9F/RJ45
  • Mechanical connection:
    • ISO 5210, flange size F14, shape A
    • ISO 5210, flange size F16, shape A
    • ГOCT P 55510, shape B, V
  • Local control unit for actuators with DMS 3 system
  • Version with control board PROFIBUS DP V0/V1
  • Version with control board MODBUS RTU

Similar products

Wedge, lid or yoke sliders

Nominal size: DN 50, DN 600 Working pressure: PN 16 Working temperature: 70 °C Connection parameters: PN EN 1092-2, ISO 7005-2 Face-to-face length: ANSI B16.1, flange design EN 558, series 15, DIN 3202-1/F5, welding version EN 12 982, series 15, (DIN 3202-1/S8)
Nominal size: DN 50, DN 600 Working pressure: PN 16 Working temperature: 70 °C

Knife gate valves

Nominal size: DN 50, DN 1000 Working pressure: PN 10/16 Working temperature: 70 °C Connection parameters: PN EN 0192-2, DIN 2501 Materials: Monolith body - ductile iron EN-GJS-400-15 (GGG-40), Wedge – fully rubberized with antibacterial EPDM, NBR, Spindle - corrosion-resistant steel 1.4021 (13% Cr), O - rings - NBR, Spindle nut – forged brass
Nominal size: DN 50, DN 1000 Working pressure: PN 10/16 Working temperature: 70 °C

Soft-sealing wedge sliders

Nominal size: DN 40, DN 1200 Working pressure: PN 10/16 Working temperature: 70 °C Connection parameters: EN 0192-2 with flanges type 21, shape B Face-to-face length: 15 – according to PN-EN 558+A1, F5 (DIN 3202), 14 – according to PN-EN 558+A1, F4 (DIN 3202)
Nominal size: DN 40, DN 1200 Working pressure: PN 10/16 Working temperature: 70 °C

Category products

Electric multi-turn actuator SOR 2PA

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 12 to 100 Nm Operating time: 10 to 40 min−1 Revolutions: 1 to 500
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 12 to 100 Nm

Electric multi-turn actuator UMR 1PA

Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 8 to 64 Nm Operating time: 10 to 80 min−1 Revolutions: 2 to 160
Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 8 to 64 Nm

Electric multi-turn actuator UMR 2PA

Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 30 to 100 Nm Operating time: 10 to 40 min−1 Revolutions: 2 to 160
Industry use: Energy, Water, Industry Enclosure protection: IP 66, IP 68 Switching-off torque: 30 to 100 Nm

Electric multi-turn actuator MOR 3PA

Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 45 to 250 Nm Operating time: 10 to 95 min−1 Revolutions: 1 to 1000
Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 45 to 250 Nm

Electric multi-turn actuator MOR 3.4PA

Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 150 to 350 Nm Operating time: 10 to 80 min−1 Revolutions: 1 to 500
Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 150 to 350 Nm

Electric multi-turn actuator MOR 5PA

Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 500 to 1000 Nm Operating time: 15 to 100 min−1 Revolutions: 1 to 800
Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 500 to 1000 Nm

Electric multi-turn actuator MOR 4PA

Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 200 to 500 Nm Operating time: 16 to 180 min−1 Revolutions: 1 to 1000
Industry use: Energy, Water, Industry Enclosure protection: IP 67 Switching-off torque: 200 to 500 Nm

Electric multi-turn actuator MOR 3.5PA

Enclosure protection: IP 67 Switching-off torque: 140 to 550 Nm Operating time: 25 to 40 min−1 Revolutions: 1 to 400 Weight: 65 to 90 kg
Enclosure protection: IP 67 Switching-off torque: 140 to 550 Nm Operating time: 25 to 40 min−1

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts