Double offset butterfly valve Series 2E

Double offset butterfly valve Series 2E

Body construction: DN 50, DN 800
Working pressure: PN 6, PN 10, PN 16, PN 25, PN 40
Working temperature: -60 to 320 °C
Marking according to: ČSN EN 19
Connection parameters: ČSN EN 1092-1, 2, ANSI B16.5 Class 150, BS10 tab. D to E
Face-to-face length: EN 558 row 20 (DIN 3202 T3 K1), ISO 5752 row 20, API 609 tab.1 EN 593
Leak test: ČSN EN12266-1, Class A, ISO 5208, Class A, API 598
Seat sealing according to: ČSN EN 1092-1, 2, ANSI RF
Tightness class: A/C

Hi, my name is Marko. I am ready to assist you.

Ing. Marko Štofan

Application: ABO's Series 2E double eccentricity butterfly valves are designed for operation in very harsh environments that require high safety, trouble-free operation and minimal maintenance. The double eccentricity design ensures safe operation and tightness even with sudden changes in temperature or pressure. The purpose of the second eccentricity is to quickly relieve the seal of compression between the closing disc and the valve seat, which extends seal life and reduces torques. As the flapper closes, the rotational motion of the disc changes to linear, effectively pushing the disc into the seal space. This design also prevents unwanted accumulation of e.g. suspended solids in contact between the disc and the sealing surfaces.

Design: WAFER type with through holes, LUG type with threaded holes, Double-flange body type with through holes  

More information from the seller

Similar products

Electric part-turn actuator SP 0-M

Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm Operating time: 15 to 160 s/90° Operating angle: 90 to 270 ° Weight: 1.4 to 2.4 kg
Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm Operating time: 15 to 160 s/90°

Electric part-turn actuator SP 0

Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm Operating time: 15 to 160 s/90° Operating angle: 90 to 270 °
Industry use: Energy, Water, Industry Enclosure protection: IP 54, IP 67, IP 68 Switching-off torque: 4 to 40 Nm

Electric part-turn actuator SP 0.1-M

Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm Operating time: 10 to 160 s/90° Operating angle: 60 to 360 ° Weight: 3.2 to 5.2 kg
Enclosure protection: IP 65, IP 67, IP 68 Switching-off torque: 16 to 50 Nm Operating time: 10 to 160 s/90°

Explosion-proof electric part-turn actuator SP 2.3-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 290 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 290 Nm

Explosion-proof electric part-turn actuator SP 2.4-Ex

Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 575 Nm Operating time: 40 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Oil and gas, Dust Enclosure protection: IP 66, IP 67 Switching-off torque: 575 Nm

Electric part-turn actuator SP 1

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 90 Nm Operating time: 10 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 90 Nm

Electric part-turn actuator SP 1-M

Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 100 Nm Operating time: 10 to 80 s/90° Operating angle: 60 to 360 ° Weight: 6.5 to 8.3 kg
Enclosure protection: IP 67, IP 68 Switching-off torque: 46 to 100 Nm Operating time: 10 to 80 s/90°

Electric part-turn actuator SP 2

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 145 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 145 Nm

Electric part-turn actuator SP 2.3

Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 290 to 350 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy, Water, Industry Enclosure protection: IP 67, IP 68 Switching-off torque: 290 to 350 Nm

Electric part-turn actuator SP 2-M

Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 175 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 ° Weight: 12 to 14.5 kg
Enclosure protection: IP 67, IP 68 Switching-off torque: 72 to 175 Nm Operating time: 5 to 80 s/90°

Category products

Triple offset butterfly valve Series 3E

Body construction: DN 80, DN 500 Working pressure: PN 25, PN 40, PN 50 Working temperature: -60 to 500 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: DN 80, DN 500 Working pressure: PN 25, PN 40, PN 50 Working temperature: -60 to 500 °C

Double offset butterfly valve Series 2E

Body construction: DN 50, DN 800 Working pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Working temperature: -60 to 320 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, 2, ANSI B16.5 Class 150, BS10 tab. D to E
Body construction: DN 50, DN 800 Working pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Working temperature: -60 to 320 °C

Double offset butterfly valves Series 2E3

Body construction: DN 150, DN 2000 Working pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Working temperature: -10 to 80 °C Connection parameters: EN 1092/BS4504 (DIN 2501), ASME B16.5 Class 150 Face-to-face length: EN 558 -1/14, ISO 5752-14, EN 558 -1/13
Body construction: DN 150, DN 2000 Working pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Working temperature: -10 to 80 °C

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts