Double 3-way valves solenoid pilot operated

Double 3-way valves solenoid pilot operated

Type: 2 x 3/2 NC
Nominal size and connection: 16 - 25 mm / G1/2 - G1
Operating pressure: 0,2 - 0,8 MPa
Enclosure protection: IP 65
Ambient temperature: -5 to 50 °C
Fluid temperature: 2 to 60 °C
Standard voltage: 230 V - AC, 24 V - DC
Input: 15 VA; 10W
Duty rating: 100 %
A type of media: filtered, lubricated compressed air
Mouting position: vertical with coils above the valve

Hello, my name is Peter.
I will be glad to help you.

Ing. Peter Kobulský 

Valve version

  • Without faulty function checking - type: 3VEE20DF, 3VEE25DF
  • With faulty function chceckingby electric limit switches - type: 3VEE20DFA, 3VEE25DFA

Requirements for installation and service 

  • Valves meet requirements of standards STN 21 0700, STN EN 692
  • Special unchoking silencer has to be used for valves
  • Residual pressure at the output 2 in case of failure is ≤ 10 % of the input pressure

Similar products

Category products

2/2 and 3/2 valves solenoid and pneumatic operated DN40

Type: 2/2, 3/2 Nominal size and connection: 40 mm / G1 1/2 Operating pressure: 0,2 - 1 MPa Enclosure protection: IP 65 Ambient temperature: -15 to 50 °C
Type: 2/2, 3/2 Nominal size and connection: 40 mm / G1 1/2 Operating pressure: 0,2 - 1 MPa

3/2 valves solenoid and pneumatic pilot operated

Type: 3/2 NC, 3/2 NO Nominal size and connection: 10 - 25 mm / G3/8 - G1 Operating pressure: 0,2 - 1 MPa Enclosure protection: IP 65 Ambient temperature: -15 to 50 °C
Type: 3/2 NC, 3/2 NO Nominal size and connection: 10 - 25 mm / G3/8 - G1 Operating pressure: 0,2 - 1 MPa

3/2 and 3/2, 4/2, 4/3 valves manual operated

Type: 3/2, 4/2, 4/3 Nominal size and connection: 10mm / G3/8 Operating pressure: 0 - 1 MPa Ambient temperature: 2 to 80 °C Fluid temperature: 2 to 80 °C
Type: 3/2, 4/2, 4/3 Nominal size and connection: 10mm / G3/8 Operating pressure: 0 - 1 MPa

5/2, 5/3 valves solenoid and 5/2 pneumatic pilot operated

Type: 5/2, 5/3 Nominal size and connection: 10mm / G3/8 Operating pressure: 0,15 - 1 MPa Enclosure protection: IP 65 Ambient temperature: -10 to 50 °C
Type: 5/2, 5/3 Nominal size and connection: 10mm / G3/8 Operating pressure: 0,15 - 1 MPa

5/2, 5/3 electrically and 5/3 pneumatically controlled

Type: 5/2, 5/3 Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 1 MPa Enclosure protection: IP 65 Ambient temperature: -15 to 50 °C
Type: 5/2, 5/3 Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 1 MPa

Double 3-way valves solenoid pilot operated

Type: 2 x 3/2 NC Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 0,8 MPa Enclosure protection: IP 65 Ambient temperature: -5 to 50 °C
Type: 2 x 3/2 NC Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 0,8 MPa

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts