Pneumatic elements

Pneumatic elements are intended for use in pneumatic mechanisms, where the main control and working signal is compressed air. For the operation of the pneumatic mechanism, a wide range of pneumatic elements can be used, from elements for air conditioning (filters and lubricators), pressure regulators, manually and mechanically, pneumatically or electro-pneumatically controlled distributors, screws to pneumomotors with accessories.

filter-icon

Products filter

Showing 49 - 60 from 121 products

Valves and solenoid valves LN series

Bezpiestnicové valce Série RLF

ATEX pneumatic cylinders ISO 6432 for harsh aggressive environment XDSM series

Pneumatic cylinders - ISO 6432

Operating pressure: 1 MPa Function: double-acting and single-acting Averages: 12, 16, 20, 25 mm Stroke: standard up to 500 mm A type of media: filtered air
Operating pressure: 1 MPa Function: double-acting and single-acting Averages: 12, 16, 20, 25 mm

Pneumatic cylinders - ISO 21287, UNITOP

Operating pressure: 1 MPa Function: double-acting and single-acting Averages: 32, 40, 50, 63, 80, 100 mm Stroke: standard up to 250 mm A type of media: filtered air
Operating pressure: 1 MPa Function: double-acting and single-acting Averages: 32, 40, 50, 63, 80, 100 mm

Pneumatic cylinders - ISO 15552

Operating pressure: 1 MPa Function: double-acting and single-acting Averages: 32, 40, 50, 63, 80, 100, 125, 160, 200, 250, 320 mm Stroke: standard up to 1000 mm A type of media: filtered air
Operating pressure: 1 MPa Function: double-acting and single-acting Averages: 32, 40, 50, 63, 80, 100, 125, 160, 200, 250, 320 mm

Air service units

Type: 2 x 3/2 NC Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 0,8 MPa Enclosure protection: IP 65 Ambient temperature: -5 to 50 °C
Type: 2 x 3/2 NC Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 0,8 MPa

Lubricator

Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Operating pressure: max. 1 MPa Ambient temperature: 5 to 60 °C Flow: 100 m3/h Fluid temperature: 5 to 60 °C
Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Operating pressure: max. 1 MPa Ambient temperature: 5 to 60 °C

Filter / regulator

Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Ambient temperature: 5 to 60 °C Inlet pressure: max. 1,2 MPa Outlet pressure: 0.02 to 1 MPa Flow: 190 m3/h
Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Ambient temperature: 5 to 60 °C Inlet pressure: max. 1,2 MPa

Pressure regulators

Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Ambient temperature: 5 to 60 °C Inlet pressure: 1,6 MPa Outlet pressure: 0.02 to 1 MPa Flow: 230 to 280 m3/h
Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Ambient temperature: 5 to 60 °C Inlet pressure: 1,6 MPa

Filters

Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Operating pressure: 0 - 1 MPa Ambient temperature: 2 to 60 °C Flow: 150 to 175 m3/h Fluid temperature: 5 to 60 °C
Nominal size and connection: 10 – 16 mm / G3/8 – G1/2 Operating pressure: 0 - 1 MPa Ambient temperature: 2 to 60 °C

Double 3-way valves solenoid pilot operated

Type: 2 x 3/2 NC Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 0,8 MPa Enclosure protection: IP 65 Ambient temperature: -5 to 50 °C
Type: 2 x 3/2 NC Nominal size and connection: 16 - 25 mm / G1/2 - G1 Operating pressure: 0,2 - 0,8 MPa