Electric multi-turn actuator UMR 1PA-M

Electric multi-turn actuator UMR 1PA-M

Enclosure protection: IP 66, IP 68
Switching-off torque: 8 to 64 Nm
Operating time: 10 to 80 min−1
Revolutions: 2 to 160
Weight: 14 to 18.5 kg
Ambient temperature: -60 to 55 °C
Flange size: F07, F10, G0

Hi, my name is Marko. I will be glad to help you.

Ing. Marko Štofan

Standard equipment and functions with DMS3 control unit

  • Supply voltage
    • 230 V / 50 Hz
  • Terminal board connection
  • Thermal protection of the electromotor 
  • Switching off in limit positions from position and from torque
  • Adjustable switching off from 50% to 100%
  • Torque blocking in limit positions
  • Torque blocking during the start
  • 2 freely programmable relays R1, R2 (18 functions) (Not valid for Profibus and Modbus)
  • Relay READY (Not valid for Profibus and Modbus)
  • Control by unified signal 0/4 - 20 mA, 4 - 12 mA, 12 - 20 mA, or 0/2 - 10 V (Not valid for Profibus and Modbus)
  • Control by permanent voltage (+24 V DC) - OPEN, CLOSE
  • Impulse control (inching duty) (+24 V DC) - OPEN, STOP, CLOSE
  • Timing mode / regime of operation
  • Safety function ESD (failure reaction)
  • Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version) (Not valid for Profibus and Modbus)
  • Auxiliary voltage output 24 V DC, max. 40 mA for supply of the control inputs and transmitter
  • Output of failure messages
  • Space heater operated by control unit
  • LED position indicator
  • Communication interface RS 232
  • Programme for parameterization setting a PC
  • Mechanical connection:
    • ISO 5210, flange size F10, shape B3, C
    • ISO 5210, flange size F07, shape B1, B2, B3, B4
  • Manual control
  • Enclosure protection IP 66

Additional equipment 

  • Supply voltage:
    • 3x400 V, 3x380 V, 220 V / 50 Hz
    • 120 V, 110 V / 60 Hz
  • Local control unit for actuators with DMS 3 system
  • Reversing unit for 3-phase supply voltage
  • Communication cable DB-9F/RJ45
  • Cable glands for armoured cables
  • Additional relays RE3, RE4, RE5
  • Additional relay module RE1, RE2, RE3, RE4, RE5, READY
  • Mechanical connection:
    • ISO 5210, flange size F10, shape A, B1
    • ISO 5210, flange size F07, shape A, B1, B2
    • MГOCT P 55510, shape AK, AČ, MK, MČ
    • DIN 3338, flange size G0, shape A, E, C
    • other non-standard
  • Version with control board PROFIBUS DP V0/V1
  • Version with control board MODBUS RTU
  • Enclosure protection IP 68

Similar products

Category products

Electric multi-turn actuator SOR 2PA-M

Enclosure protection: IP 67, IP 68 Switching-off torque: 12 to 100 Nm Operating time: 10 to 40 min−1 Revolutions: 1 to 500 Weight: 12 to 18.5 kg
Enclosure protection: IP 67, IP 68 Switching-off torque: 12 to 100 Nm Operating time: 10 to 40 min−1

Electric multi-turn actuator UMR 1PA-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 8 to 64 Nm Operating time: 10 to 80 min−1 Revolutions: 2 to 160 Weight: 14 to 18.5 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 8 to 64 Nm Operating time: 10 to 80 min−1

Electric multi-turn actuator UMR 2PA-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 30 to 100 Nm Operating time: 10 to 40 min−1 Revolutions: 2 to 160 Weight: 20 to 27 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 30 to 100 Nm Operating time: 10 to 40 min−1

Electric multi-turn actuator MOR 3PA-M

Enclosure protection: IP 67 Switching-off torque: 45 to 250 Nm Operating time: 10 to 95 min−1 Revolutions: 1 to 1000 Weight: 33 kg
Enclosure protection: IP 67 Switching-off torque: 45 to 250 Nm Operating time: 10 to 95 min−1

Electric multi-turn actuator MOR 4PA-M

Enclosure protection: IP 67 Switching-off torque: 200 to 500 Nm Operating time: 16 to 180 min−1 Revolutions: 1 to 1000 Weight: 85 kg
Enclosure protection: IP 67 Switching-off torque: 200 to 500 Nm Operating time: 16 to 180 min−1

Electric multi-turn actuator MOR 5PA-M

Enclosure protection: IP 67 Switching-off torque: 500 to 1000 Nm Operating time: 15 to 100 min−1 Revolutions: 1 to 800 Weight: 95 kg
Enclosure protection: IP 67 Switching-off torque: 500 to 1000 Nm Operating time: 15 to 100 min−1

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts