STANDARD ATOM

Electric actuators for nuclear power stations are designed to active duty located outside containment with reactors of type VVER. They can be used for the selected devices of the security class II and III (2 and 3).
The main characteristic features of the electric actuators for nuclear plants:
• 40 years lifetime
• seismicity resistance up to 8g (within a frequency interval 4-35 Hz)
• functional resistance to an emergency environment HELB (3-6 hours), in the fume environment with a temperature 110 °C and pressure ranged between 0,2
• seismic group 1a
filter-icon

Products filter

Switching-off torque

X

Enclosure protection

X

Flange size

X
Showing 1 - 10 from 10 products

Electric part-turn UP 2.5-A

Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 250 to 1200 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 250 to 1200 Nm

Electric part-turn actuator UP 2.4-A

Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 180 to 800 Nm Operating time: 5 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 180 to 800 Nm

Electric part-turn actuator UP 2-A

Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 75 to 300 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 75 to 300 Nm

Single-turn electric servo drive UP 1-A

Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 22 to 100 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 68 Switching-off torque: 22 to 100 Nm

Electric part-turn actuator SP 2.4-A

Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 575 Nm Operating time: 40 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 575 Nm

Electric part-turn actuator SP 2.3-A

Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 290 Nm Operating time: 20 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 290 Nm

Electric part-turn actuator SP 2-A

Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 72 to 145 Nm Operating time: 5 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 72 to 145 Nm

Electric part-turn actuator SP 1-A

Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 46 to 90 Nm Operating time: 10 to 80 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 46 to 90 Nm

Electric part-turn actuator SP 0.1-A

Industry use: Energy Enclosure protection: IP 67 Max. load moment: 50 Nm Operating time: 10 to 160 s/90° Operating angle: 60 to 360 °
Industry use: Energy Enclosure protection: IP 67 Max. load moment: 50 Nm

Electric part-turn actuator SP 0-A

Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 4 to 40 Nm Operating time: 15 to 160 s/90° Operating angle: 90 to 270 °
Industry use: Energy Enclosure protection: IP 67 Switching-off torque: 4 to 40 Nm