Multi-turn

Multi-turn electric actuators transmit torque to a valve or on gearbox for at least one revolution. These actuators, equipped with a linear adapter, may be capable of withstanding thrust. They are used to control wedging and knife gate valves, resilient seated gate valve and valves with a screw. For mechanical connection to different designes of valve is available version with rising or non-rising spindle with enclosure rating IP 66, IP 67 and IP 68. 
filter-icon

Products filter

Switching-off torque

X

Enclosure protection

X

Flange size

X
Showing 1 - 9 from 9 products

Explosion-proof electric multi-turn actuator UM 1-Ex-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 4 to 64 Nm Operating time: 10 to 80 min−1 Revolutions: 3.125 to 160 Weight: 14 to 15 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 4 to 64 Nm Operating time: 10 to 80 min−1

Explosion-proof electric multi-turn actuator UMR 1PA-Ex-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 8 to 64 Nm Operating time: 10 to 80 min−1 Revolutions: 2 to 160 Weight: 14 to 15 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 8 to 64 Nm Operating time: 10 to 80 min−1

Explosion-proof electric multi-turn actuator UM 2-Ex-M

Type number: 137 Enclosure protection: IP 66, IP 68 Switching-off torque: 18 to 100 Nm Operating time: 10 to 40 min−1 Revolutions: 3.125 to 160
Type number: 137 Enclosure protection: IP 66, IP 68 Switching-off torque: 18 to 100 Nm

Explosion-proof electric multi-turn actuator UMR 2PA-Ex-M

Enclosure protection: IP 66, IP 68 Switching-off torque: 30 to 100 Nm Operating time: 10 to 40 min−1 Revolutions: 2 to 160 Weight: 26 to 27 kg
Enclosure protection: IP 66, IP 68 Switching-off torque: 30 to 100 Nm Operating time: 10 to 40 min−1

Explosion-proof electric multi-turn actuator MO 3-Ex-M

Enclosure protection: IP 66 Switching-off torque: 26 to 150 Nm Operating time: 16 to 95 min−1 Revolutions: 1 to 685 Weight: 45 to 55 kg
Enclosure protection: IP 66 Switching-off torque: 26 to 150 Nm Operating time: 16 to 95 min−1

Explosion-proof electric multi-turn actuator MOR 3PA-Ex-M

Enclosure protection: IP 66 Switching-off torque: 40 to 150 Nm Operating time: 16 to 95 min−1 Revolutions: 1 to 1000 Weight: 46 to 57 kg
Enclosure protection: IP 66 Switching-off torque: 40 to 150 Nm Operating time: 16 to 95 min−1

Explosion-proof electric multi-turn actuator MO 4-Ex-M

Enclosure protection: IP 66, IP 55 Switching-off torque: 95 to 500 Nm Operating time: 16 to 180 min−1 Revolutions: 1.75 to 685 Weight: 70 to 85 kg
Enclosure protection: IP 66, IP 55 Switching-off torque: 95 to 500 Nm Operating time: 16 to 180 min−1

Explosion-proof electric multi-turn actuator MO 5-Ex-M

Enclosure protection: IP 66 Switching-off torque: 300 to 1000 Nm Operating time: 15 to 100 min−1 Revolutions: 1.25 to 500 Weight: 93.5 to 103 kg
Enclosure protection: IP 66 Switching-off torque: 300 to 1000 Nm Operating time: 15 to 100 min−1

Explosion-proof electric multi-turn actuator MOR 5PA-Ex-M

Enclosure protection: IP 66 Switching-off torque: 500 to 1000 Nm Operating time: 15 to 100 min−1 Revolutions: 1 to 800 Weight: 94.5 to 104 kg
Enclosure protection: IP 66 Switching-off torque: 500 to 1000 Nm Operating time: 15 to 100 min−1